Through our global network of testing experts and analytical equipment including chromatography (HPLC, GC, GC/MS) and atomic absorption spectroscopy (AAS, GFA, FIAS), Our goal is to provide test services as efficiently as possible to maximize our customers' profits. For more information about our services, contact one of our experts today.
Note: this service is for Research Use Only and Not intended for clinical use.
AA-090 Lambda 950
The Ultraviolet/Visible/Near Infrared Spectrophotometer can be used for qualitative identification and quantitative analysis of measured substances according to their absorption spectra inultraviolet, visible and near infrared light. The functions of spectrometry, photometry and time change measurement are often utilized to material identification, purity inspection, structure analysis, reaction dynamics and solution balance research. Lambda 950 based on excellent system configuration, good optical performance, automated operation is the most advanced in the field.The system has high performance ultraviolet/visible/near infrared which can be applied at 3300 nm wavelength and suitable for such as high and low reaction coating, coating color correction, ultraviolet, visible and near infrared filter characterization applications.
Optics
Materials
Biotechnology
Pharmaceuticals
coatings and so on
Specifications-Lambda 950 Ultraviolet/Visible/Near Infrared Spectrophotometer | ||
---|---|---|
Photometric Performance | principle | double beam |
wavelength coverage | 175 - 3300 nm | |
bandwidth | ≤0.05 nm | |
wavelength coverage | 175 - 3300 nm | |
linearity range | 8A | |
wavelength accuracy | ±0.08 nm | |
stray light | ≤0.00007%T | |
baseline drift | <0 0002A/h | |
noise factor | <0 00005A | |
Instrument Specification | height | 30.0 cm |
width | 102.0 cm | |
weight | 77.0 kg | |
operating temperature | 15 ~35°C |
Universal Reflectance Accessory (URA) - plug and play module, automatic variable Angle –PerkinElmeris unique.
The Incomparable sample room size is tailor-made for your sample.
Optional detector can measure all kinds of samples including scattered and turbid samples.
The optimum SNR can be obtained without the original smoothing data.
Sample module replacement takes only a few seconds.
Do not know how to place an order, please refer to the flow chart shown below.
Submit quotation request |
A technical manager will contact you within 24 hours |
You will review and approve the final price and place an order |
Confirm with you and make the payment |
Instruct you to ship your samples and form |
Analytic report delivery |