Through our global network of testing experts and analytical equipment including chromatography (HPLC, GC, GC/MS) and atomic absorption spectroscopy (AAS, GFA, FIAS), Our goal is to provide test services as efficiently as possible to maximize our customers' profits. For more information about our services, contact one of our experts today.
Note: this service is for Research Use Only and Not intended for clinical use.
Using differential scanning calorimeter (DSC), we can study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polycrystalline phenomenon of drugs and so on. DSC 204 F1 Phoenix is used to study the thermal effects of materials at controlled temperature. It provides liquid nitrogen, mechanical refrigeration, air compression and cooling cup for different cooling methods. The Tau-sensor has good separation ability to the overlapping thermal effects, the µ-sensor has a high level of calorimetric sensitivity, and can be selected according to different detection needs.
Phase transition of inorganic materials.
Melting and crystallization of polymer materials.
Glass transition.
Oxidative stability.
Polycrystalline phenomenon of drugs.
Solid/liquid ratio of foods such as fats and oils.
Melting point of metals and alloys.
Widely used in plastics, rubber, coatings, adhesives, pharmaceuticals, petrochemical and other fields.
Specifications-DSC 204 F1 Phoenix | |
---|---|
Temperature Range | -180°C to 700°C |
Heating Rates | 0.001 K/min to 200 K/min |
Cooling Rates | max. 200 K/min |
Compressed Air Cooling | RT to 700°C |
Intracooler for the Extended Range | -85°C to 600°C |
Automatically Controlled LN2 Cooling | -180°C to 700°C |
Indium Response Ratio | >160 mW/K Peak Height [mW]/Peak with at 50% Height [K] of Indium melting peak |
Automatic Sample Changer | for 192 samples and reference crucibles (optional) |
Determination of onset, peak, inflection and end temperatures
Automatic peak search
Evaluation of crystallization
Comprehensive glass transition analysis
Automatic baseline correction
Specific heat determination
Sector-specific software solutions for conformance to e.g. GLP and GMP
Do not know how to place an order, please refer to the flow chart shown below.
Submit quotation request |
A technical manager will contact you within 24 hours |
You will review and approve the final price and place an order |
Confirm with you and make the payment |
Instruct you to ship your samples and form |
Analytic report delivery |