Through our global network of testing experts and analytical equipment including chromatography (HPLC, GC, GC/MS) and atomic absorption spectroscopy (AAS, GFA, FIAS), Our goal is to provide test services as efficiently as possible to maximize our customers' profits. For more information about our services, contact one of our experts today.
Note: this service is for Research Use Only and Not intended for clinical use.
Acrylamide is limited in coffee roasting, coffee powder and instant coffee in the United States because of its neurotoxicity and potential carcinogenicity. At present, there are many methods for the determination of acrylamide in coffee, each of which has its own advantages and disadvantages. This white paper mainly introduces four methods for the determination of acrylamide in coffee: GC, HPLC, GC-MS and LC-MS, and summarizes the latest progress in the determination of acrylamide in various kinds of coffee.
At present, the determination of acrylamide in coffee is mainly based on instrumental analysis, and the general chemical analysis can not meet the requirements of food analysis. After some extraction and purification, GC, HPLC, MS and their combination for qualitative and quantitative detection are the current common detection methods.
Gas chromatography (GC)
GC can be divided into two types of gas-solid chromatography and gas-liquid chromatography due to the different stationary phases used. The former uses a solid adsorbent as a stationary phase, and the latter uses a monomer coated with a fixing solution as a stationary phase. There are many types of detectors that can be used in GC. The most commonly used are flame ionization detector (nD) and thermal conductivity detector (TCD). Both detectors are sensitive to many analytical components and can be used to determine concentrations in a wide range. TCD is universal in nature and can be used to detect any substance except carrier gas, while FID is mainly sensitive to hydrocarbons. FID is more sensitive to hydrocarbon detection than TCD, but it cannot be used to detect water. Both detectors are powerful. Because the detection of TCD is non-destructive, it can be used in series with the destructive FID (connected before the FID), thus giving two complementary analytical information to the same analyte.
Gas chromatography-mass spectrometry (GC-MS)
GC-MS has an effective ability to separate and distinguish organic compounds, while MS is an effective means to accurately identify compounds. The GC-MS technology, which is composed of the combination of the two, can be used to directly separate complex mixture samples by gas chromatography under the control of a computer, so that the compounds in the mixture can be entered into the ion source of the mass spectrometer one by one, and all the compounds in each sample can be ionized by means of electron bombardment or chemical ionization, and each compound regularly forms a series of fragment ions and molecular ions. Then, under the action of magnetic field (or electric field), scan and record according to the mass-charge ratio of these ions, and finally use the computer to process the data, according to the chromatographic retention time of each compound, as well as the fracture pattern of molecular ions and key fragment ions in mass spectrometry, combined with standard samples or standard spectra, the compounds are qualitatively identified and quantitatively analyzed one by one.
High performance liquid chromatography (HPLC)
HPLC is an important branch of chromatography. Using liquid as mobile phase, using high-pressure infusion system, the mobile phase, such as single solvent with different polarity or mixed solvent with different proportion and buffer solution, is pumped into a chromatographic column with fixed phase. After the components in the column are separated, they enter the detector for detection, so as to realize the analysis of samples. This method has become an important separation and analysis technology in the fields of chemistry, medicine, industry, agriculture, commodity inspection and legal inspection.
Liquid chromatography-mass spectrometry (LC-MS)
LC-Ms is a combination of liquid chromatography and mass spectrometry. It combines the effective separation of liquid chromatograph and strong component identification of mass spectrometer. It is an effective means to separate and analyze complex organic mixtures. The key to online is the development of a suitable interface, and the solvent must be removed before the sample components enter the ion source.
Because green coffee beans are an unfinished food, the acrylamide content in green coffee beans has little to do with human health. At present, few scholars have determined the acrylamide content in green coffee beans. Nowadays scholars also use some methods to determine the acrylamide content in roasted coffee, coffee filter and instant coffee, namely GC, GC-MS, HPLC and LC-MS / MS. The results of detection of acrylamide in various kinds of roasted coffee and instant coffee are shown in Table 1.
Table 1 Content of Acrylamide in coffee roasting and instant coffee
Serial Number | Acrylamide Content in Coffee/(μg/kg) | Determination Method | Detector | Sample Preparation | References | |
---|---|---|---|---|---|---|
Coffee Roasting | Instant Coffee | |||||
1 | 1000~17500 | GC-FID | Shimadzu GC, RTX-5 | Hot water dissolution | 1 | |
2 | 131.8~191.2 | GC-MS | Agilent GC-6890N, MSD-5975N | Water dissolution, brominated with sodium thiosulfate | 2 | |
3 | 210~330 | 23.8~42.2 | GC-MS | Agilent GC-6890N, MSD-5975N | Hot water dissolution | 3 |
4 | 40~600 | GC-MS | Agilent GC-6890N, MSD-5975N | Water dissolution, brominated with sodium thiosulfate | 4 | |
5 | 57~181 | 237~476 | GC-MS | HP GC-6890, Agilent MSD-5973N | Ethanol dissolution | 5 |
6 | 52~191 | HPTLC | HPTLC System | Derivatization to dansulfinic acid | 6 | |
7 | 374~3800 | HPLC-LFD | Agilent HP1100-MSD | Derivatization to dansyl chloride | 7 | |
8 | 43.4~464.8 | 42~338 | LC-MS/MS | TSQ Quantum System | Water dissolution, adding dichloromethane | 8 |
9 | 115~237.5 | 180~225 | LC-MS/MS | HP1100 HPLC, Quantum Ultima | Water dissolution | 9 |
10 | 64~374 | 172~471 | LC-MS/MS | LC-MS System, Agilent 1100 HPLC | Water dissolution | 10 |
11 | 206~356 | 715~865 | LC-MS/MS | LC-MS/MS System Alliance 2695 | Water dissolution | 11 |
12 | 109~250 | HPLC-MS | HP-1100 series LC-MSD system | Distilled water dissolution | 12 | |
13 | 163~313 | 349~499 | LC-MS/MS | LC-MS System Shodex RSpak DE-413L | Distilled water dissolution | 13 |
14 | 1020 | LC-MS/MS | Agilent LC-MS/MS, Acquity UPLC HSS T3 | Distilled water dissolution | 14 | |
15 | 140~159 | 81~101 | LC-MS/MS | HP-1100 series LC-MSD system | Distilled water dissolution | 15 |
16 | 150~327 | LC-MS/MS | HP-ESI-MS/MS System, Finnigan LXQ | Distilled water dissolution | 16 | |
17 | 130~1250 | LC-MS/MS | Dionex UltiMate 3000, Hypercarb | Water dissolution | 17 | |
18 | 61~379 | 152~830 | LC-MS/MS | Dionex UltiMate 3000, Hypercarb | Water dissolution | 18 |
19 | 62~261 | LC-MS/MS | HP GC-6890, MSD-5973N | Ethanol dissolution | 19 | |
20 | 13~468 | LC-MS/MS | UPLC System, TQ detector | Formic acid dissolution | 20 | |
21 | 267.7 | 806.9~1492.4 | LC-MS/MS | Agilent LC-MS/MS | Derivatization to 2-mercaptobenzoic acid | 21 |
22 | 12~29 | 42~338 | LC-MS/MS | Agilent 1100 HPLC, Agilent 1100 MS | Methanol dissolution | 22 |
23 | 17~320 | LC-MS/MS | Agilent 1100 HPLC, Agilent 1100 MS | Methanol dissolution | 23 |
Acrylamide in coffee was determined by GC, HPLC, GC-MS and LC-MS/MS. GC-MS and LC-MS / MS are the most widely used methods. The method for the determination of acrylamide includes three steps: extraction, purification and chromatographic separation. The difference lies in the use of different extractants, derivates and chromatographic separation methods. There are some differences in precision and sensitivity of all kinds of detection methods. Different coffee varieties, roasting degree and detection methods also have great influence on the content of acrylamide in coffee, and the highest content of acrylamide in coffee is 17500 (μg/kg). There are many levels of coffee roasting, and each level of roasting has a unique smell and taste, but only a few levels of acrylamide content have been determined. For the sake of people's healthy diet, it is necessary to determine the content of acrylamide for all kinds of coffee and the degree of roasting of all kinds of coffee to evaluate the quality of coffee.
Madihah KY, Zailiunnisa A H, Norashikin S, et al. Optimization of roasting conditions for high—quality Arabica coffee [J]. International Food Research Journal, 2013, 20(4): 1623-1627.
Alves R C, Soares C, Fernandes S C J O, et al. Acrylamide in espresso Coffee: Influence of species, roast degree and brew length [J]. Food Chemistry, 2010, 119(3): 929-934.
Cristina M D S, Rita C A, Susana C, et al. Development and Validation of a Matrix Solid-Phase Dispersion Method to Determine Acrylamide in Coffee and Coffee Substitutes [J]. Journal of food science, 2010, 75(3): 57-63.
Minseok C. Enzymatic control of the acrylamide level in coffee [J]. Eur Food Res Technol, 2013, 236(3): 567-571.
Soares C, Cunha S, Femandes J. Determination of acrylamide in coffee and coffee products by GC—MS using an improved SPE clean-up [J]. Food Additives and Contaminants, 2006, 23(12): 1276-1282.
Alpmann A, Morlock G. Rapid and Cost-Effective Determination of Acrylamide in Coffee by Planar Chromatography and Fluorescence Detection After Derivatization with Dansulfinic Acid [J]. Journal of AOAC international, 2009, 92(3): 725-729.
Bagdonaite K, Derler K, Murkovic M. Determination of Acrylamide during Roasting of Coffee [J]. J Agric Food Chem, 2008, 56(15): 6081-6086.
Aguas P C, Fitzhenry M J, Giannikopoulos G, et al. Analysis of acrylamide in coffee and cocoaby isotope dilution liquid chromatography-tandem mass spectrometry [J]. Anal Bioanal Chem, 2006, 385(8): 1526-1531.
Granby K, Fagt S. Analysis ofacrylamide in coffee and dietary exposure to acrylamide from coffee [J]. Analytlca Chimica Acta, 2004, 520(1): 177-182.
Andrzejewski D, Roach J G, Gay M, et al. Analysis of Coffee for the Presence of Acrylamide by LC-MS/MS [J]. J Agric Food Chem, 2004, 52(7): 1996-2002.
Adriana A P, Toledo M C F, Govaert Y, et al. A Modified Sample Preparation for Acrylamide Determination in Cocoa and Coffee Products [J]. Food Anal. Methods, 2008, 1(1): 49-55.
Gianni S, Armando F, GabrieUa M, et al. HPLC—MS validation of Qualisa Foo® biosensor kit for cost-effective control of acrylamide levels in Italian coffee [J]. Food Control, 2007, 18(1): 1267-1271.
Delatour T, Perissot A, Goldmarm T. et al. Improved Sample Preparation to Determine Acrylamide in Difficult Matrixes Such as Chocolate Powder, Cocoa, and Coffee by Liquid Chromatography Tandem Mass Spectroscopy [J]. J Agric Food Chem, 2004, 52(15): 4625--4631.
Aklllloglu H G, Grkmen V. Mitigation of acrylamide and hydroxymethyl furfural in instant coffee by yeast fermentation [J]. Food Research International, 2014(61): 252-256.
Troise A D, Fiore A. Fogliano V. Quantitation of Acrylamide in Foods by High—Resolution Mass Spectrometry [J]. J Agric Food Chem, 2014, 62(1): 74-79.
Bortolomeazzi R, Munari M, Anese M, et al. Rapid mixed mode solid phase extraction method for the determination of acrylamide in roasted coffee by HPLC-MS/MS [J]. Food Chemistry, 2012, 135(4): 2687-2693.
Wenzl T, Szilagyi S, Rosen J, et al. Validation by collaborative trial of an isotope dilution liquid chromatographic tandem mass spectrometric method to determine the content of acrylamide in roasted coffeee [J]. Food Additives and Contaminants, 2009, 26(8): 1146-1152.
Mojska H, Gielecinska I. Studies of Acrylamide level in coffee and coffee substitutes: influence of raw material and manufacture condition [J]. Rocz Panstw Zakl Hig, 2013, 64(3): 173-181.
Pardo O, Yuset V, Coscolla C, et al. Determination of acrylamide in coffee and chocolate by pressurised fluid extraction and liquid chroatography—tandem mass spectrometry [J]. Food Additives and Contaminants, 2007, 24(7): 663-672.
Kocadagh T, Goncuoglu N, Hamzabogh A, et al. In depth study of acrylamide formation in coffee during roasting: role of sucrose decomposition and lipid oxidation [J]. Food Funct, 2012(3): 970-975.
Granvogl M, Schiebede P. Quantification of 3-aminopropionamide in cocoa, coffee and cereal products. Correlation with acrylamide concentrations determined by an improved clean-up method for complex matrices [J]. Eur Food Res Technol. 2007, 225(5): 857-863.
Senyuva H Z S, Gokmcn V. Study of acrylamide in coffee using an improved liquid chromatography mass spectrometry method: Investigation of colour changes and acrylamide formation in coffee during roasting [J]. Food Additives and Contaminants, 2005, 22(3): 214-220.
Gokmen V, Senyuva H Z. Study of colour and acrylamide formation in coffee, wheat flour and potato chips during heating [j]. Food Chemistry, 2006, 99(2): 238-243.
Alfa Chemistry Testing Lab is the world's leading third-party testing company, which can provide one-stop coffee testing solutions for manufacturers and consumers.
Do not know how to place an order, please refer to the flow chart shown below.
Submit quotation request |
A technical manager will contact you within 24 hours |
You will review and approve the final price and place an order |
Confirm with you and make the payment |
Instruct you to ship your samples and form |
Analytic report delivery |